APPLICATIONS:
Mud resistant In accordance with NEK 606, the cables shall have a sheath (SHF MUD) that complies with the requirements in IEC 60092-359 for SHF 2 sheath materials.
Oil & Gas For control, lighting and power systems on oil and gas rigs.
Marine For fixed wiring installations on oil and gas rigs, shipboard and other marine applications requiring screened cable for EMC.
PRODUCT FEATURES:
- Low smoke halogen free
- Mud resistant to NEK606
- PVC free
- Lloyds approved
- UV stabilised
- Flame retardant
- To be earthed at both ends using EMC compatible glands
- Heat, oil and chemical resistant (see Chemical Rating Chart)
CONSTRUCTION:
Conductor Annealed tinned copper stranded (Class 2).
Insulation Halogen free EPR (Ethylene Propylene Rubber).
Inner Sheath SHF 2, thermoset dual compound LSHF and oil/mud resistant.
Screening Tinned copper braid screen.
Sheath SHF 2, thermoset dual compound LSHF and oil/mud resistant.
CHARACTERISTICS:
Operating Temperature Range Fixed -40°C to 90°C.
Maximum Conductor temperature 90°C (Current ratings are based on 30°C air temp. See technical section for de-rating factors).
Rated Voltage Uo/U 0.6/1kV Max AC Operating Voltage Uo 0.7kV.
Sheath Colour Black.
Standard Core Colours
Single Core – White.
2 Core – White and Black.
3 Core – White, Black and Red.
4 Core – Off-White, Black, Red and Blue.
Certification Society Approvals Lloyds Register of Shipping.
Relevant Standards NEK606, IEC 60092-353, IEC 60092-351, IEC 60092-359, IEC 60754-1/2, IEC 61034-1, IEC 61034-2, IEC 60228, IEC 60332-3-22, ROHS Compliant.