TCGEL02/2/1.5

2 PAIR x 1.5mm2


High Performance Fixed Instrumentation Traffic Feeder Cable 300V 70°C


Keywords: TC Feeder Series, Gel Filled, Overall Screen, Individual Pair Screen

 

Click to download full series data sheet

Click to download Compliance Document

Quantity of item required. Cable is quoted in metres.

APPLICATIONS:


Traffic Signals Gel filled instrumentation cables for traffic signal installations.


PRODUCT FEATURES:



  • UV resistant

  • Flame retardant

  • Heat, oil and chemical resistant (see Chemical Rating Chart).


CONSTRUCTION:


Conductor Annealed plain copper stranded (Class 2).

Insulation LDPE.

Cable Filler Transparent LDPE.

Water Block Material Gel filled with water block tape to AS/NZS 2276.2.

TCGEL-ES (Individual Pair Screen) PET+ Aluminium/Polyster tape screen applied with 7/0.25mm TC drain wire complete with gel compound.

TCGEL (Overall Screen) Aluminium/Polyster tape screen applied with 7/0.25mm TC drain wire and gel compound.

Screening Collective shield of aluminium/polyester foil complete with tinned copper drain wire (7/0.25mm tinned copper).

Sheath PVC 4V-75.


CHARACTERISTICS:


Operating Temperature Range Fixed -20°C to 70°C.

Maximum Conductor Temperature 70°C (Current ratings are based on 30°C air temp. See technical section for de-rating factors).

Max. Conductor Resistance 13.6 Ω/kM.

Min. Insulation Resistance 20G Ω/kM @ 500Vdc.

Mutual Capacitance 65-80nF/kM @ 1kHz.

Max. Water Penetration 3% Maximum variation of C3 between cores.

Rated Voltage 300V.

Minimum Bending Radius 12 x cable diameter.

Sheath Colour Black.

Standard Core Colour  

PAIR 1: Blue, Blue with White Stripe.

PAIR 2: Orange, Orange with White Stripe.

PAIR 3: Green, Green with White Stripe.

PAIR 4: Black, Black with White Stripe.

NOTE: THE CABLE HAS A PAIR TO NUMBER MARKING ON THE SHEATH FOR IDENTIFICATION PURPOSES.

Relevant Standards AS/NZS 2276.2 (exception to overall diameter for 2 & 4 pair cables), AS/NZS 1125, AS/NZS 1660, AS/NZS 1049 and ROHS Compliant.


COMPLIANCE DOCUMENT:


TC FEEDER Certificate of Compliance

No. of Cores x Size (mm²): 2 PAIR 1.5

Approx. Stranding (No. of wires x mm): 7/0.5

Insulation Thickness (mm): 0.5

Thickness of Inner Sheath (mm): 0.8

Thickness of Outer Sheath (mm): 1.2

Approx. Overall Diameter (mm): 13.4